28 June 2015 to 3 July 2015
Africa/Johannesburg timezone
SAIP2015 Proceeding published on 17 July 2016

In-situ neutron powder diffraction temperature capabilities at SAFARI-1

1 Jul 2015, 11:50
20m
Oral Presentation Track F - Applied Physics Applied

Speaker

Dr Michael Hayes (Necsa)

Would you like to <br> submit a short paper <br> for the Conference <br> Proceedings (Yes / No)?

yes

Level for award<br>&nbsp;(Hons, MSc, <br> &nbsp; PhD, N/A)?

no

Please indicate whether<br>this abstract may be<br>published online<br>(Yes / No)

yes

Abstract content <br> &nbsp; (Max 300 words)<br><a href="http://events.saip.org.za/getFile.py/access?resId=0&materialId=0&confId=34" target="_blank">Formatting &<br>Special chars</a>

The recently commissioned neutron powder diffractometer at the SAFARI-1 reactor of Necsa, aptly named Powder Instrument for Transition in Structure Investigations (PITSI), is equipped with both heating and cooling sample environments to allow in-situ temperature dependent studies in the temperature range 3 K to 1800 K. SAFARI-1 is a 20 MW light-water moderated tank-in-pool materials testing reactor that has an in-core flux of 4×〖10〗^14 neutrons cm-2s-1. The monochromatic flux of the PITSI instrument at the sample position is ≈ 106 neutrons cm-2s-1. The interchangeable heating and cooling sample environments were both procured from AS Scientific Products Ltd., UK and are specifically configured for use on neutron scattering instruments. The closed-cycle cryostat is equipped with a SHI Cryogenics RDK-408D2 cold head rendering 1W cooling power at 3.5 K, which in conjunction with a LakeShore 340 temperature controller, facilitates achieving accurate temperatures covering the range 3 K < T < 350 K. The vacuum furnace employs radiant heat generated and focussed with a 3600 W Niobium element and heat shrouds in conjunction with a West 4100+ temperature controller covers temperatures from 300 K to 1800 K. Both these sample environments are under full computer control. Temperature set points can be maintained to accuracies better than ±1 K and logged throughout the data acquisition. With envisaged modifications, the furnace system could be extended to incorporate in-situ reaction chambers.
PITSI in conjunction with its temperature environments, amongst others enable in-situ studies of chemical and / or magnetic phase transitions, determination of thermal expansion coefficients, quantification of phases, etc. A number of investigations have been completed and will be reported on to demonstrate the capabilities of this instrument that is available to the research community under the R&D User Program.

Apply to be<br> considered for a student <br> &nbsp; award (Yes / No)?

no

Primary author

Dr Michael Hayes (Necsa)

Co-authors

Presentation Materials

There are no materials yet.